38
SURVIVOR 390HE Installation Manual
Measurement Rate
15 measurements/sec, nominal
Input Sensitivity
155 nV per internal count
System Linearity
Within 0.01% of full scale
Zero Stability
155 nV/
°C, maximum
Span Stability
4.0 ppm/
°C, maximum
Calibration Method
Software, constants stored in
EEPROM
Common Mode
Voltage
2.5
±.25 VDC
Rejection
140 dB minimum @ 50 or 60 Hz
Normal Mode
Rejection
90 dB minimum @ 50 or 60 Hz
Input Overload
± 12 V continuous, static discharge
protected
RFI Protection
Signal, excitation, and sense lines
protected by capacitor bypass
Digital Specifications
Microcomputer
Phillips P51XAG30 microcontroller @
12.288 MHz
Digital Filters
3 filters, software selectable
Serial Communications
EDP/Printer Port
Full duplex RS-232
19 200, 9600, 4800, 2400, 1200, 600,
300 bps; 8 data bits, no parity, or 7
data bits, even or odd parity
Operator Interface
Display
6-digit LCD display: 7-segment, 1.0 in
(25 mm) digits
Additional Symbols
Annunciators for gross, net, standstill,
center of zero, tare, low battery.
annunciators for units (lb/kg), piece
count mode (PC). Adhesive labels
provided for units other than lb and kg.
Keyboard
5 pushbutton switches
Environmental
Operating Temperature –10 to +40
°C (legal);
–10 to +50
°C (industrial)
Storage Temperature
–25 to +70
°C
Humidity
0–95% relative humidity
Altitude
2000 m (6500 ft) maximum
Enclosure
Enclosure Dimensions:
Weight
6.8 Lb (3.1 Kg)
Shipping Weight: 7.5 Lb (3.4 Kg)
Rating/Material
NEMA 4X
Certifications and Approvals
NTEP
CoC Number
98-203
Accuracy Class
III/III L
n
max
: 10 000
Measurement Canada
Approval
AM-5300
Accuracy Class
III
n
max
: 10 000
III HDn
max
: 20 000
Measurement Canada
Approval
AM-xxxx
Accuracy Class
III
n
max
: 10 000
III HDn
max
: 20 000
T
D I G I T A L W E I G H T I N D I C A T O R
MODE
ENTER
SAMPLE
I/O
ZERO
GROSS
NET
TARE
UNITS
T
B/N
Units
POWER
lb
kg
PC
10.50"
8.50"
6.30"