8 specifications – Rice Lake Survivor 390HE Hostile Environment Digital Indicator User Manual
Page 41

Appendix
37
Figure 8-6. Front Panel Key Functions in Test Mode
8.8
Specifications
Power
Line voltages
115 VAC
Frequency
50 or 60 Hz
Power Consumption
100 mA (using 4 x 350W load cells)
Analog Specifications
Full Scale Input Signal Up to 17 mV
Excitation Voltage
5
± 0.25 VDC,
4 x 350
Ω or 8 x 700Ω load cells
Sense Amplifier
Differential amplifier with
4- and 6-wire sensing
Analog Signal
Input Range
–2.5 mV/V – 22.5 mV/V
Sensitivity
0.3
μV/graduation minimum,
1.5
μV/grad recommended
Input Impedance
200 M
Ω, typical
Noise (ref to input)
0.3
μV p-p with digital filters at 4-4-4
Internal Resolution
2
20
(approx. 1 000 000) counts
Display Resolution
999 999 dd
TEST Menu
Function
Description
A/DTST
Display A/D test
Press and hold Enter key to display raw count from A/D converter.
ADOFFS
A/D offset calibration (–0.5 mv/V)
Read Caution! statement on page 36 before using this function. Press and hold the setup switch, then press the
Enter key to perform offset calibration.
ADGAIN
A/D gain calibration (+4.5 mv/V)
Read Caution! statement on page 36 before using this function. Press and hold the setup switch, then press the
Enter key to perform gain calibration.
DEFLT
Default parameters
Press and hold the setup switch, then press the Enter key to reset configuration and calibration parameters to
factory default values. This function is equivalent to using the RESETCONFIGURATION EDP command followed
by the RS (reset) EDP command.
PRTCFG
Print configuration
Press the Enter key to print the indicator configuration to the serial port. This function is equivalent to using the
DUMPALL EDP command.
Table 8-5. Test Menu Functions
ASCII 02
decimal
Polarity:
<–> = Negative
Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.
L = pounds
K = kilograms
T = metric tons (T)
G = grams
OZ, TN, NONE
G = Gross
N = Net
Status:
I = Invalid
M = Motion
O = Over/under range
or