6.8
Inclinometer
lb
On dump trucks and roll off applications, the
LoadRunner
system uses load
pins and a hydraulic pressure transducer to determine a weight value. To
achieve the best accuracy, calibrate the system at the same incline that will be
used for determining the weight value, within ±1-2 degrees.
The inclinometer setup screen shows both the body angle in a numeric value
and absolute angle (abs 0.0). For this application, use the level indicators that
light up for every degree the body is raised.
The numeric value will indicate a negative value as the body is raised. This is
normal. The level to the right will light up one circle at a time.
The inclinometer function allows visual determination of the height the body
achieves to accurately weigh consistently.
6.8.1 Calibrate the Inclinometer
1. Ensure the truck is on a level surface and the body is in the down
position.
2. In MENU, select
Options
.
3. Press
(OK).
4. In OPTIONS menu, select
Inc.
5. Press
(OK).
6. Press
to select
On
.
7. Press
CAL
to calibrate the inclinometer.
8. Press
(OK)
to confirm inclinometer zero.
9. Press
to return to options menu.
Inclinometer screen will be added to the MENU options.