8 scoreboard format 6, 9 scoreboard format 7 – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual
Page 22

18
OB-350 Operators Manual
6.5.8
Scoreboard Format 6
Data is output in the following format every 60 seconds:
$GPVWS,
type = 01
Unit type 01 = M350S under body weigher: LOADWEIGH
sgn = “+” or “-“
Sign of Net – plus sign = positive, minus sign = negative
net
Net weight – 5 characters
gvw
Gross Vehicle Weight – 5 characters
alarm1
Alarm 1 set point – 5 characters
alarm2
Alarm 2 set point – 5 characters
Set 1
N = Net, G = Gross: S = Sounder, P = PPCO: 0 = not Activated, 1 = Activated
Set 2
N = Net, G = Gross: S = Sounder, P = PPCO: 0 = not Activated, 1 = Activated
HHMMSS
Hours, Minutes and Seconds
DDMTYY
Day, Month and Year
*XX
Checksum
Example:
Net = 15000kg, gvw = 25000kg, alarm 1 Net sounder at 15500kg, alarm 2 Gross PPCO at 26000kg
$GPVWS,01,+,15000,25000,15500,26000,NS0,GP0,164100,280210*XX
Net = 15900kg, gvw = 25900kg, alarm 1 Net sounder activated at 15500kg, alarm 2 Gross PPCO at
26000kg $GPVWS,01,+,15900,25900,15500,26000,NS1,GP0,164200,280210*XX
6.5.9
Scoreboard Format 7
Data is output in the following format for interface with a BA484D Serial Display:
Variable
Parameters
n = 1 or 2 Input Variable number, where 1 = net & 2 = gross, string = any 7-bit numeric ASCII string
The
numeric value as a simple ASCII string. The syntax is
updated (= 1 or 2) and string is the numeric value to be displayed.
Example:
The command