3 alarms menu, 1 alarm setpoints, 2 set alarm – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual
Page 17

Technical Settings
13
6.3
Alarms Menu
6.3.1
Alarm Setpoints
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
lb
Allows configuration of the audible alarm.
Table 6-1. Alarm Setpoints Menu
Parameter
Choices
Description
Alarm
Alarm ON
Turns alarm on.
Alarm OFF
Turns alarm off.
Output
Output Normal
+12 VDC to power and alarm on power connector.
Output Invert
-12 VDC to power and alarm on power connector.
Gross
Gross PPCO
Not used (custom packer-plate configuration only).
Net Sounder
Alarm will display speaker and beep when net weight
reaches Alm value entered.
Net PPCO
Not used (custom packer-plate configuration only).
Inc Sounder
For use with inclinometers only – activates alarm when
angle reaches above incline (inclinometer setting) in
degrees.
Inc PPCO
Not used (custom packer-plate configuration only).
Gross Sounder
Alarm will display speaker and beep when gross weight
reaches Alm value entered.
Alm
Alarm Weight
Value
Edit value of the net or gross weight for alarm.
Hys
Hysteresis Value
Not currently available.
Trigger
Off
On
2,5,10 seconds – selectable delay prior to alarm
activating in seconds.
6.3.2
Set Alarm
1. In MENU, select
Alarms
.
2. Press
(OK)
3. Two setpoints appear. Select
Alarm 1
.
4. Pressing
(OK)
toggles between
ON
and
OFF
. Select
ON
.
5. Pressing
(OK)
toggles between
Output Normal
and
Output Invert
.
6. Pressing
(OK)
toggles between
Gross-Sounder
,
Net-Sounder
,
Gross-PPCO
or
Net-PPCO
.
7. Select
Alm
. The alarm (sounder or flashing beacon) will activate at
weight displayed. To change target weight, press
edit
and set the alarm
setpoint using techniques in previous steps.
8. Select
HYS
, reset tolerance is edited in lb using techniques in previous steps.
9. Select
Trigger,
then press
(OK)
to toggle between:
OFF
,
2
,
5
or
10
seconds.
10. When all settings are correct, press
(OK)
to confirm.
11. For alarm 2, select
Alarm 2
and repeat steps 7-10.