2.5 Optional 920i Weighcenter Mounting
1. Before installing the bracket a bead of silicone must be added. See Figure 2-9.
(Apply silicone where labeled adhesive)
2. Clean the wall tubes where bracket will mount and the space between the holes
on the mount bracket with mineral spirits.
3. Install the adhesive tape on the mounting bracket between the holes.
4. Place the mounting bracket onto the cage wall by pressing the adhesive tightly
to the cage.
5. Secure with four bolts.
Figure 2-9. Weighcenter Mounting
6. Mount the weighcenter onto the mounting bracket and route the cable as shown
in Figure 2-9.
7. Install the clamps to secure the conduit.
• Mount the upper conduit clamp using the lower left mounting bracket bolt.
• Secure the lower end of the conduit by drilling a hole through the cage
sheeting and installing the clamp with the bolt provided.
Battery Box Connections
1. Connect the scale cable and secure with a cable tie.
2. Connect the power wires as shown in Figure 2-10.
3. Replace the battery cover.
Figure 2-10. Battery Connections
Adhesive
Conduit Clamp 9/32Ш