IQ plus 390-DC Installation Manual
3.2.4
Serial Menu
See Section 8.2 on page 32 for information about the IQ plus 390-DC serial data format.
Figure 3-8. Serial Menu
XXXXXXX
XXXXXXX
EOLDLY
000000
number
BITS
TERMIN
BAUD
CR
9600
7ODD
7EVEN
8NONE
CR/LF
4800
2400
1200
600
300
LFT
OFF
STREAM
INDUST
VERS
PROGRM
PFORMT
SERIAL
CALIBR
CONFIG
FORMAT
19200
SERIAL Menu
Parameter
Choices
Description
Level 2 Submenus
BAUD
9600
19200
300
600
1200
2400
4800
Baud rate. Selects the transmission speed for the EDP port.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data transmitted from the EDP port.
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the EDP port.
EOLDLY
0
number
End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line is
terminated to the beginning of the next formatted serial output. Value specified must be in the
range 0-255, in tenths of a second (10 = 1 second).
STREAM
OFF
LFT
INDUST
Selects whether continuous data output is streamed from the serial port. Select LFT for legal-for-
trade applications in which the streamed data must match the current displayed weight. Select
INDUST to stream the latest weight data, regardless of the value displayed.
See Section 8.2 on page 32 for information about the IQ plus 390-DC continuous data format.
Table 3-5. Serial Menu Parameters