6.5.1. Span Adjustment
This Mode Is Provided To Calibrate Scale
Accessing Calibration Mode
1. Press and hold down the [REZERO] key.
2. While holding , press the [
←
←
←
← DIGIT] key, the [TARE] key, the
[TARE] key.
3. Then release the [REZERO] key.
In This Mode, Each Key Functions As Follows
[
↑↑↑↑ INCREASE] key Used to increase value of digit
[
←
←
←
← DIGIT] key
Used to change digits as needed
[REZERO] key
Used to save changes and advance through
calibration
[TARE] key
Used to exit calibration mode without
saving changes
[18]
6.3. Set Up And Calibration
6.3.1. Specification Change
Function key for spec. change.
Accessing Operational Specs. (50 – 59)
1. Press and hold down the [REZERO] key.
2. While holding , press the [
←
←
←
← DIGIT] key three times .
3. Then release the [REZERO] key.
In This Mode, Each Key Functions As Follows
[
←
←
←
← DIGIT] key
Used to input 0
[
↑↑↑↑ INCREASE] key
Used to input 1
[REZERO] key
Used to save the specification and increment to
the next specification
[TARE] key
Used to exit from specification mode
THE SLEEP TIMER IS LOCATED IN OPERATIONAL SPECS.
Spec.50 = sleep timer ( 0000 = none to 1111 = 15 min. )
6.3.2. Specification Change (Continued)
Function key for spec. change.
Accessing Weights & Measures Specs. (00 – 09 / 20 – 29)
1. Press and hold down the [REZERO] key.
2. While holding , press the [
←
←
←
← DIGIT] key, the [TARE] key, the[←
←
←
←
DIGIT] key.
3. Then release the [REZERO] key.
In This Mode, Each Key Functions As Follows
[
←
←
←
← DIGIT] key
Used to input 0
[
↑↑↑↑ INCREASE] key Used to input 1
[REZERO] key
Used to save the specification and increment to
the next specification
[TARE] key
Used to exit from specification mode