Battery life check, Spec setting – Rice Lake Digi DI-28SS Bench Scale User Manual
Page 12

5.3. Battery Life Check
The battery life can be checked
PROCEDURE KEY
OPERATION DISPLAY INDICATOR
0 NET
Stand-by status
0.000
♦
1. Press [TARE],
[ ], [TARE] key
while pressing [RE-
ZERO] key.
+ , ,
2. Press [TARE] key
to beback to weighing
mode.
0.000
♦
The number of boxes in the display indicates the battery power. When batteries are fully charged,
6 boxes appear. As the battery is running out of power, the number of boxes will decrease
gradually.
[10]
Options (continued)
7.4.3. Spec
Setting
SPEC 52 Bit 2
Send STX before text
0 No
1 Yes
SPEC 52 Bit 3
Handshaking for RS232 output
0 No
1 Yes
SPEC 53 Bit 0
Send Header as text
0 No
1 Yes
SPEC 53 Bit 1
RS232C data sending method
0
Send immediately 1 After data is stable
SPEC 53 Bit 2
RS232 data format
0 Without
header
1 With
header
SPEC 53 Bit 3
Stable flag in RS232C
0
Without stable flag
1
With stable flag
SPEC 54 Bit 0, 1 and 2 RS232C baud rate
0 0 0
1200
0 1 0
4800
1 0 0
19200
0 0 1
2400
0 1 1
9600
SPEC 54 Bit 3
RS232C output
0 Disable
1 Enable
SPEC 55 Bit 0
RS232C data length
0 7
bit
1 8
bit
SPEC 55 Bit 1
RS232C stop bit
0 1
bit
1 2
bits
SPEC 55 Bit 2 and 3
RS232C parity bit
0 0
No parity 0 1
Odd
1 0
Even
SPEC 59 Bit 0 and 1
RS232C time out error
0 0
1 sec
1 0
5 sec
0 1
3 sec
1 1
10 sec
SPEC 59 Bit 2
Stream / Manual method
0 Stream
1 Manual
SPEC 59 Bit 3
Remote trigger for RS232C
0 Disable
1 Enable
[23]
0
T
T
T