4 indicator operations, 1 weighing mode operations, Weighing mode operations – Rice Lake 120 Digital Weight Indicator User Manual
Page 7

Introduction
3
See Section 3.2.2 on page 12 for more information about configuring primary and secondary display units.
Table 1-1. Units Annunciators, Showing Primary / Secondary LEDs Used for All Configurations
Primary Unit
Secondary Unit
lb
kg
oz
g
tn
t
none
lb
lb / lb
lb / kg
lb / oz
lb / g
lb / kg
kg
kg / lb
kg / kg
kg / oz
kg / g
lb / kg
oz
oz / lb
oz / kg
oz / oz
oz / g
oz / kg
g
g / lb
g / kg
g / oz
g / g
g / kg
tn
lb / kg
lb / kg
lb / oz
lb / g
lb / lb
lb / kg
lb / kg
t
lb / kg
lb / lb
lb / kg
none
lb / kg
lb / kg
lb / lb
1.4
Indicator Operations
1.4.1
Weighing Mode Operations
Basic 120 operations are summarized below:
Toggle Gross/Net Mode
Press the
GROSS/NET
key to switch the display mode from gross to net, or from net to gross. If a tare value has
been entered or acquired, the net value is the gross weight minus the tare.
Gross mode is shown by the
Gross
annunciator; net mode is shown by the
Net
annunciator.
Toggle Units
Press the
UNITS
key to switch between primary and secondary units. The units LED to the right of the display is
lit.
Zero Scale
1. In gross mode, remove all weight from the scale and wait for the standstill annunciator (
).
2. Press the
ZERO
key. The center of zero (
) annunciator lights to indicate the scale is zeroed.
Acquire Tare
1. Place container on scale and wait for the standstill annunciator (
).
2. Press the
TARE
key to acquire the tare weight of the container. The indicator switches to net mode.
Remove Stored Tare Value
1. Remove all weight from the scale and wait for the standstill annunciator (
).
2. Press the
TARE
key. The indicator switches to gross mode, indicating the tare value has been removed.
Print Ticket
1. Wait for the standstill annunciator (
).
2. Press the
key to send data to the serial port.