Rice Lake 120 Digital Weight Indicator User Manual
Page 17

Configuration
13
Level 3 submenus
Primary Units (PRIMAR Parameter)
DECPNT
888888
8.88888
88.8888
888.888
8888.88
88888.8
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.
DSPDIV
1D
2D
5D
10D
20D
50D
Display divisions. Selects the minimum division size for the primary units displayed weight.
UNITS
LB
KG
OZ
TN
T
G
NONE
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; TN=short ton; T=metric ton; G=gram.
Secondary Units (SECNDR Parameter)
DECPNT
88888.8
888888
8.88888
88.8888
888.888
8888.88
Decimal point location. Determines the location of the decimal point or dummy zeros in
the secondary unit display.
DSPDIV
5D
10D
20D
50D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight.
UNITS
KG
OZ
TN
T
G
LB
NONE
Specifies secondary units for displayed and printed weight. Values are: KG=kilogram;
OZ=ounce; TN=short ton; T=metric ton; G=gram; LB=pound.
MULT
0.45359
number
Multiplier. Specifies the conversion factor by which the primary units are multiplied to
obtain the secondary units. The default is 0.45359, which is the conversion factor for
changing pounds to kilograms. Use the MULEXP parameter to shift the decimal position
of the multiplier. See Section 7.5 on page 33 for a list of multipliers.
To toggle between primary and secondary units, press the UNITS key.
MULEXP
dec_position
Multiplier decimal shift. Specifies a divisor used to shift the decimal position in the
secondary units multiplier value. Use the left and right arrow keys to shift the decimal point
within the displayed MULT value.
FORMAT Menu
Parameter
Choices
Description
Table 3-3. Format Menu Parameters (Continued)