beautypg.com

Operating the charger, Choose chemistry hold for more, Choose chemistry [chemistry] @[voltage – ProgressiveRC 10S FMA Cellpro User Manual

Page 9

background image

9

Operating the charger

You operate the charger using the Mode button and Start/Stop button:

Mode button: enables you to select a preset, change preset values and—during charging—

display charging data.

Start/Stop button: enables you to select an optimization method, start charging, and stop

charging.

This section provides detailed instructions for all these operations.

Selecting the optimization method

Press the Start button quickly to select the desired optimization method:

ACCURATE CHARGE : charging stops when all cells are at exactly the target voltage.

FASTER CHARGE : charging stops when the pack draws less than 10% of the set charge

current, regardless of individual cell voltages. Since balancing begins early in the charge

cycle, significant balancing still takes place.

Selecting a preset

To determine the currently selected preset and review its settings: Press the Mode button on

the charger’s right side.

To select a different preset: Press the Mode button until you see the desired preset’s name

and settings in the display, then wait until you see the

SAFE TO CONNECT screen.

The preset displayed when you stop pressing the

Mode button is the “selected” preset. Once the

preset is selected, you can change the charge settings for this preset (see “Changing a preset”) or

begin charging by pressing the Start/Stop button.

Note: The Charge Control Software enables you define up to six custom presets. If

you have defined custom presets, you can—at the charger—select any preset. (If you

have not defined custom presets, the two factory presets are available.)

Changing a preset

You can change the charge settings for the currently selected preset to match the characteristics

of the pack(s) you are charging.

Note: Changes you make to presets are saved in the charger when the charger is dis-

connected from power.

1. Select the preset you want to change (see “Selecting a preset,” above).
2. At this point, there are several things you can do:

To change the chemistry:

a. Press and hold the

Mode button, then release it when the display changes to this:

Choose Chemistry

Hold for More

Note: If you hold the Mode button down longer, you’ll see

Choose Chg. Amps

or

Exit

(both described below).

When you release the Mode button, you’ll see the chemistry setting:

Choose Chemistry

[chemistry] @[voltage]