Ch1 [chemistry] done ch2 [chemistry] done – ProgressiveRC 10S FMA Cellpro User Manual
Page 12

12
To stop charging: Press the Start/Stop button for one second. The charger displays the
Home screen.
Note: Pack data is lost when you leave Charging Mode, so if you want to see it, do so
before pressing the
Start/Stop button.
Note: If you restart the charge, you might see a
Please wait...
screen. The
charger is discharging capacitors, which may take up to one minute. When reinitializa-
tion is complete, charging will begin again.
5. When charging is complete, the display below will appear, and the charger will beep for about
30 seconds to alert you.
Ch1 [chemistry] DONE
Ch2 [chemistry] DONE
To review final data for the pack(s): Press the Mode button to cycle through the data
screens.
Note: Pack data is lost when you leave Charging Mode, so if you want to see it, do so
before pressing the
Start/Stop button.
To leave Charging Mode: Press the Start/Stop button.
Alternate charging modes
Based on what the charger determines about charging conditions, it may enter one of these charg-
ing modes (as indicated in the display):
In Low Voltage Restore Mode, the charger automatically attempts to repair an overdischarged
pack. Cells discharged as low as 0.5V may be repaired to as much as 98% of capacity.
In Safety Charging Mode, the charger detects that at least one cell is seriously out of bal-
ance, and automatically lowers charge current to 0.5A.
CAUTION: If the charger’s display shows
SAFETY CHARGING
during several
attempts at charging, the pack is damaged. Treat damaged packs with caution. Do not
charge them on a flammable surface, and do not charge them unattended.
In Cold Weather Balancing Mode, charging automatically stops at 4.10V/cell when tem-
perature is below 55°F to prevent cell damage.
If the charger detects a problem, it will stop charging and display a safety code. If this happens:
1. Press the
Mode button to reset the charger.
2. Reconnect the battery properly.
3. Press the
Start/Stop button to continue charging.