beautypg.com

Choose chg. amps hold for more, Choose chg. amps charge @ [current, Exit hold for more – ProgressiveRC 10S FMA Cellpro User Manual

Page 10

background image

10

b. Press and release the Mode button until you see the chemistry you want. Choices are:

Lithium Poly 4.20V

Lithium Ion 4.20V

Lithium Ion 4.10V

A123 3.65V

To change the charge current:

a. Press and hold the

Mode button, then release it when the display changes to this:

Choose Chg. Amps

Hold for More

Note: If you hold the Mode button down longer, you’ll see

Exit

(described below)

or

Choose Chemistry

(described above).

When you release the Mode button, you’ll see the charge current setting:

Choose Chg. Amps

Charge @ [current]

b. Then:

Press the Mode button about once per second to increase current in 0.1A steps.

Press the Mode button quickly twice to increase current to the next Amp.

When the maximum current is reached, press the Mode button once for each of the

following three Auto charge modes or Storage charge mode:

1.0C (where C = pack’s capacity)

2.0C

3.0C

Store (to charge pack to about 50% capacity; optimum for long-term

storage)

(Return to charge current settings at 0.1A)

Note: The charger’s Auto charge fuel gauge tables are optimized for Lithium Cobalt

batteries. If you are charging Lithium Manganese batteries, Auto charge modes may

take twice as long as expected. Manual current settings are recommended when charg-

ing Lithium Manganese batteries.

To save the settings and return to the Home screen: Press and hold the Mode button, then

release it when the display changes to this:

Exit

Hold for More

Note: If you hold the Mode button down longer, you’ll see

Choose Chemistry

or

Choose Chg. Amps

(both described above).

or

To save the settings and begin charging if a pack is connected to the charger: Press the

Start/Stop button on the charger’s right side. Details are provided in the next section.