Pack wiring issues can cause nuisance safety codes. If any of the safety codes below appear, try

connecting the pack to the banana jacks and node connectors without using the plug blocker.

Safety code Problem

60-65

Positive switch close failure

66-71

Series switch close failure

72-77

Negative switch close failure

78

Greater than 42V detected

79-80

Cell count out of range (internal software check)

81-86

Charge switch close failure

87

Voltage steady timeout

88

Check Pack 1 voltage out of range

89

Check Pack 2 voltage out of range

90-92

Internal software check

93

Calibration checksum error. Charger must be returned to factory for calibration.

Specifications

For battery type

Lithium Polymer, Lithium Ion, Lithium Manganese and A123 packs;

charger can be used with 1s to 10s packs having node connectors and

connected to charger with an appropriate FMA adapter cable

Pack capacity

100mAh to 65Ah (charge time limited to maximum of 12 hours)

Input voltage

10 to 16VDC, reverse polarity protected

Input current

Up to 25A; can be limited to 1A to 25A in 0.25A increments

Power conversion

62.5kHz switcher operating at 90% efficiency

Nominal output voltage

3.60, 4.10 and 4.20 volts per cell; 42V maximum

Output current

Up to 10A when charging through discharge leads and node connector

Up to 4A when charging through node connector only

Both conditions reverse polarity protected

Current is automatically controlled

Cell balancing

To within 1mV with 0.1mV resolution

Voltage calibration

Cell voltage measurements are factory calibrated to 1ppm (50μV)

traceable to NIST

Internal switches

Four internal FET switches series-connect packs to enable charge

through node connectors only; switches close only after proper pack

connection is verified; maximum switch current limited to 4A

Plug blocker

Prevents reverse polarity connection to banana jacks after internal

switches are closed; charger looks for 4.7kohm resistor when using

internal switches

Current calibration

Charge current is factory calibrated on a 4A standard; calibration is to

±5mA

Measurement accuracy Absolute voltage accuracy: ±2mV from 0 to 50V

Charge current: ±1%

Capacity added to pack: ±1%

Percent capacity (“Fuel”): ±5%

Internal resistance

0.1mV voltage resolution allows accurate four point internal resistance

measurement of each cell

Serial data output

19.2kbps, 8 bits, 1 start bit, 1 stop bit, no parity; CRC16 checksum

Firmware updates

Encrypted at factory, decrypted in charger