90 osc-25_inch, 90 outside corner 1/4” glass – Oldcastle BuildingEnvelope HP-1750 User Manual
Page 34
34
JULY 2011
H P - 1 7 5 0
I N S T A L L A T I O N M A N U A L
Web Address: www.oldcastlebe.com
Phone: 1-866-OLDCASTLE (653-2278)
90 OUTSIDE CORNER 1/4” GLASS
HP-10457
HP-10465
HP-10487
HP-10488
ATTACH W/ FS-55
@ 18" O.C.
SEAL CONTINUOUS
MODIFIED HP175-FP-47
DIVERTER. BED IN SEALANT
& SEAL AS SHOWN
HP-10455
HP175-FP-57
MULL CAP. BED IN
SEALANT & ATTACH
W/ FS-202. LOCATE
AT HEAD & SILL
REFERENCE SHEET
# 8 FOR TYPICAL
MULL CAP
INSTALLATION
MITER DETAIL
3/8"
DLO +
9/16"
0