beautypg.com

Mullion reinforcing, Installing mullion reinforcing – Oldcastle BuildingEnvelope HP-1750 User Manual

Page 19

background image

21

JULY 2011

H P - 1 7 5 0

I N S T A L L A T I O N M A N U A L

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)

INSTALLING MULLION REINFORCING

HP-10434

HP-10390

HP-10414 REINFORCEMENT

ATTACH W/ FS-43

(#12 X 3/4" PPH) @

HEAD & SILL ONLY

POSITION REINFORCEMENT TO

FIT AGAINST WALL OF

MULLION TO PROVIDE MAXIMUM

CLEARANCE FOR MULL FILLER

3/8" X 3 3/4" STEEL

BAR. CUT LENGTH TO BE

MULL LENGTH MINUS 2"

AND INSET 1" FROM EACH

END. ATTACH W/ FS-43

AT EACH END OF STEEL.

HP-10390

HP-10434

SECURE HP-10414 REINFORCING

WITH FS-43 ABOVE AND BELOW

STEEL.