6 power supply requirements, Power supply requirements -7 – Cabletron Systems SEHI-22FL User Manual
Page 22

Power Supply Requirements
SEHI User’s Guide
3-7
JAM Output Specifications
Collisions are propagated through the network using the JAM signal of an
alternating pattern of 1’s and 0’s in accordance with 802.3 specifications
for a repeater unit.
Fragment Extension Specifications
Fragments are extended to a minimum of 96 bits using the JAM [1,0].
Fault Protection Specifications
Each segment disconnects itself from the other segments if 32 consecutive
collisions occur, or if the collision detector of a segment is on for longer
than approximately 110
µ
s. This fault protection resets automatically after
one packet is transmitted/received onto the fault protected segment
without causing a collision.
3.6
POWER SUPPLY REQUIREMENTS
The SEHI has a universal power supply. The input power requirements
are listed in Table 3-2.
The power supply has two outputs of +5 Vdc and +12 Vdc. The maximum
output power is 40 W and the minimum efficiency is 65% under all
conditions of the line at full load. The minimum and maximum load
currents from each output are listed in Table 3-3.
Table 3-2
Power Requirements
Model
Voltage Range
Frequency Range
SEHI-22FL
100–125 Vac
or 200–250 Vac
50/60 Hz
Table 3-3
Power Supply Output Specifications
Output
Min. Load
Max. Load
Max Power
+5 Vdc
0.75 A
4 A
20 W
+12 Vdc
0.00 A
2 A
24 W
SEHI Book Page 7 Friday, April 19, 1996 10:46 AM