Electrical specifications, Mechanical specifications, Environmental specifications – Kontron KISS 2U KTQ87 User Manual
Page 45

12. Technical Data
KISS 2U V2 MB_SBC– User's Guide (Version 1.00)
12.1. Electrical Specifications
The corresponding electrical specifications of your KISS 2U V2 platform can be found on the type label.
12.2. Mechanical Specifications
Dimensions
KISS 2U V2 (Standard Version)
Height
2U (88 mm) (3.5”)
Width
Front: 19”; Chassis: 430 mm (16.9")
Depth
Chassis: 472.3 mm (18.6")
Weight
(without packaging)
Aprox. 10.00 kg (22.046 lbs.)
Chassis
Chassis, black (RAL 7021)
Front access panel: blue (RAL 5017)
12.3. Environmental Specifications
Thermal Management
2x system fan (temperature-controlled)
PSU fan
CPU fan
Operating Temperature /
Relative Humidity
0 … +50 °C @5-95 % not condensing [at +55 °C (131 °F) at 10% POH per month]
(32 .. 122 °F @5-95 % not condensing [+55 °C (131 °F) at 10% POH per month]
Storage / Transport
Temperature / Relative
Humidity
-20 … +70 °C @ 5-95 % not condensing
(-4 … 158 °F @ 5-95 %) not condensing
Max. Operation Altitude
2,000 m (6,560 ft)
Max. Storage / Transport
Altitude
10,000 m (32,810 ft)
Operating Shock
15 G, 11 ms, half sine
Storage / Transit Shock
30 G., 11 ms, half sine
Operating Vibration
10 – 500 Hz, 1.0 G
Storage / Transit Vibration
10 – 500 Hz, 2.0 G
Acoustic Noise
< 35 dB(A) (at 1 m in front of the system, full load)
∼ 40 dB(A) for systems with Intel® Quad Core™ processor or redundant PSU
www.kontron.com
43