5 environmental specifications, 1 temperature, 1 commercial temperature – Kontron COMe-cPV2(v1.0) User Manual
Page 17: 2 industrial temperature, Environmental specifications, Temperature

Kontron microETXexpress-PV User’s Guide
www.kontron.com
13
3.5
Environmental Specifications
3.5.1
Temperature
3.5.1.1 Commercial Temperature
Operating Temperature (with Kontron heat spreader plate
assembly):
»
Ambient temperature: 0 to 60°C
»
Heat spreader-plate temperature range: 0°C - 60°C
»
Non-operating: 0°C to 60°C
NOTES:
1) The maximum operating temperature with the heat spreader plate
installed is the maximum measurable temperature on any spot on the heat
spreader surface. You must maintain the temperature according to the
specification above.
2) The design incorporates vendor-qualified industrial temperature
rated components (-40 to +85°C) where available.
Operating (without Kontron heat spreader plate assembly):
»
Maximum operating temperature: 0-60°C
»
Non operating: 0°C to 60°C
NOTE:
**The maximum operating temperature is the maximum measurable
temperature on any spot on the module surface. You must maintain the
temperature according to the specification above.
3.5.1.2 Industrial Temperature
Operating Temperature (with Kontron heat spreader plate
assembly):
»
Ambient temperature: -40°C to 85°C
»
Non-operating: -40°C to 85°C
NOTES:
1) The maximum operating temperature with the heat spreader plate
installed is the maximum measurable temperature on any spot on the heat
spreader surface. You must maintain the temperature according to the
specification above.
2) The design incorporates vendor-qualified industrial temperature
rated components (-40 to +85°C) where available.