Atx mode / single supply mode – Kontron COMe-cSP2 User Manual
Page 46
![background image](/manuals/637998/46/background.png)
COMe-cSP2
/ COMe-cSP2 Connector
41
ATX Mode / Single Supply Mode
ATX Mode:
By connecting an ATX power supply, PWR_OK is set to low level and VCC is off. Press the power button to enable the
ATX PSU setting PWR_OK to high level and powering on VCC. The ATX PSU is controlled by the PS_ON# signal which is
generated by SUS_S3# via inversion.
ATX Mode
State
PWRBTN#
PWR_OK
V5_StdBy
PS_ON#
VCC
G3
x
x
0V
x
0V
S5
high
low
5V
high
0V
S5 -> S0
PWRBTN Event
low -> high
5V
high -> low
0 V-> VCC
S0
high
high
5V
low
VCC
Single Supply Mode:
In single supply mode the module will start automatically when VCC power is connected and Power Good input is open
or at high level (internal PU to 3.3V). PS_ON# is not used in singly supply mode.
To power on the module from S5 state press the power button or reconnect VCC
Single supply mode
State
PWRBTN#
PWR_OK
V5_StdBy
VCC
G3
x
x
x
0
G3 -> S0
high
open / high
x
connecting VCC
S5
high
open / high
x
VCC
S5 -> S0
PWRBTN Event
open / high
x
reconnecting VCC
- All columbs marked with an ―x‖ are not important for the specific power state.
- All ground pins have to be tied to the ground plane of the carrier board.