Kontron KTUS15-mITX - 1.1 Basic User Manual
Page 12

KTD-00774-G
KTUS15/mITX
Page 12 of 84
Environmental
Conditions
Operating:
0°C – 60°C operating temperature (forced cooling). It is the customer’s responsibility
to provide sufficient airflow around each of the components to keep them within
allowed temperature range.
10% - 90% relative humidity (non-condensing)
Storage:
-20°C – 70°C
5% - 95% relative humidity (non-condensing)
Electro Static Discharge (ESD) / Radiated Emissions (EMI):
All Peripheral interfaces intended for connection to external equipment are ESD/ EMI
protected.
EN 61000-4-2:2000 ESD Immunity
EN55022:1998 class B Generic Emission Standard.
Safety:
UL/IEC 60950-1 2nd edition
- 2007-03-27.
CSA C22.2 No. 60950-1-03 2nd edition - 2007-03-01.
IEC 60950-1:2005+A1
Product Category: Information Technology Equipment Including Electrical Business
Equipment
Product Category CCN: NWGQ2, NWGQ8
File number: E194252
Theoretical MTBF:
353.685 hours @ 40ºC, 170.050 hours @ 60ºC.
Restriction of Hazardeous Substances (RoHS):
All boards in the KTUS15 board family are RoHS compliant.
Capacitor utilization:
No Tantalum capacitors onboard
Only Japanese brand Aluminum capacitors rated for 100º Celsius used onboard
Battery
Exchangeable 3.0V Lithium battery for onboard Real Time Clock and CMOS RAM.
Manufacturer Panasonic / PN CR2032NL/LE, CR-2032L/BN or CR-2032L/BE.
Expected minimum 5 years retention varies depending on temperature, actual
application on/off rate and variation within chipset and other components.
Approximately current draw is 3-4 µA (no PSU connected).
CAUTION: Danger of explosion if the battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.