4.8 Printer Port Connector (PRINTER).
The signal definition in standard printer port mode is as follows:
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
2K2
(24)/24
OC(O)
STB#
1
2
AFD#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD0
3
4
ERR#
I
-
2K2
2K2
24/24
IO
PD1
5
6
INIT#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD2
7
8
SLIN#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD3
9
10
GND
PWR
-
-
2K2
24/24
IO
PD4
11
12
GND
PWR
-
-
2K2
24/24
IO
PD5
13
14
GND
PWR
-
-
2K2
24/24
IO
PD6
15
16
GND
PWR
-
-
2K2
24/24
IO
PD7
17
18
GND
PWR
-
-
2K2
-
I
ACK#
19
20
GND
PWR
-
-
2K2
-
I
BUSY
21
22
GND
PWR
-
-
2K2
-
I
PE
23
24
GND
PWR
-
-
2K2
-
I
SLCT
25
26
GND
PWR
-
-
The interpretation of the signals in standard Centronics mode (SPP) with a printer attached is as follows:
Signal
Description
PD7..0
Parallel data bus. The bus are able to operate in PS/2 compatible bi-directional mode.
SLIN#
Signal to select the printer sent from CPU board to printer.
SLCT
Signal from printer to indicate that the printer is selected.
STB#
This signal indicates to the printer that data at PD7..0 are valid.
BUSY
Signal from printer indicating that the printer cannot accept further data.
ACK#
Input indicating that the printer has received the data and is ready to accept further data.
INIT#
This active low output initializes (resets) the printer.
AFD#
This active low output causes the printer to add a line feed after each line printed.
ERR#
Signal from printer indicating that an error has been detected.
PE#
Signal from printer indicating that the printer is out of paper.
The printer port additionally supports operation in the EPP and ECP mode as defined in [3].
Connecting the cable kit 821026 “Cable LPT 2mm 250mm” to the mITX or the 821031 “Cable LPT 2.54mm
250mm” implements the standard DB-25 interface:
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
2K2
(24)/24
OC(O)
STB#
1
14
AFD#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD0
2
15
ERR#
I
-
2K2
2K2
24/24
IO
PD1
3
16
INIT#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD2
4
17
SLIN#
OC(O)
(24)/24
2K2
2K2
24/24
IO
PD3
5
18
GND
PWR
-
-
2K2
24/24
IO
PD4
6
19
GND
PWR
-
-
2K2
24/24
IO
PD5
7
20
GND
PWR
-
-
2K2
24/24
IO
PD6
8
21
GND
PWR
-
-
2K2
24/24
IO
PD7
9
22
GND
PWR
-
-
2K2
-
I
ACK#
10
23
GND
PWR
-
-
2K2
-
I
BUSY
11
24
GND
PWR
-
-
2K2
-
I
PE
12
25
GND
PWR
-
-
2K2
-
I
SLCT