background image

4.1e.

If selected a

Lo-Shelv_1

(first order Low Shelving) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] ----

:

:

:

20kHz

+15.0 dB

----

4.1f.

If selected a

Lo-Shelv_2

(second order Low Shelving) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] ----

:

:

:

20kHz

+15.0 dB

----

4.1g.

If selected a

Lo-Shelv_Q

(variable Q Low Shelving) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] 0.30

:

:

:

20kHz

+15.0 dB

20.00

4.1h.

If selected a

Lo-Pass_1

(first order Low Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----

[Freq.] 20Hz

[Amp.] -----

[Q] ----

:

:

:

20kHz

-----

----

4.1i.

If selected a

Lo-Pass_2

(second order Low Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ----

[Freq.] 20Hz

[Amp.] -----

[Q] ----

:

:

:

20kHz

-----

----

4.1l.

If selected a L

o-Pass_Q

(variable Q Low Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00

[Freq.] 20Hz

[Amp.] -----

[Q] 0.30

:

:

:

20kHz

-----

20.00

4.1m.

If selected a

Hi-Pass_1

(first order High Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----

[Freq.] 20Hz

[Amp.] -----

[Q] ----

:

:

:

20kHz

-----

----

4.1n.

If selected a

Hi-Pass_2

(second order High Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ----

[Freq.] 20Hz

[Amp.] -----

[Q] ----

:

:

:

20kHz

-----

----

4.1o.

If selected a

Hi-Pass_Q

(variable Q High Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00

[Freq.] 20Hz

[Amp.] -----

[Q] 0.30

:

:

:

20kHz

-----

20.00

4.1p.

If selected an

All-Pass_1

(first order All Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----

[Freq.] 20Hz

[Amp.] -----

[Q] ----

:

:

:

20kHz

-----

----

4.1q.

If selected an

All-Pass_2

(second order, variable Q All Pass) filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00

[Freq.] 20Hz

[Amp.] -----

[Q] 0.30

:

:

:

20kHz

-----

20.00

4.1r.

If selected a

Band Pass

filter, then the filter can be set by

the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00

[Freq.] 20Hz

[Amp.] -15.0 dB

[Q] 0.30

:

:

:

20kHz

+15.0 dB

20.00

4.1s.

If selected a

Notch Filt

filter,

then the filter can be set by the following parameters

Input A/B

EQ-[x] (up to 5 filters available)

[Freq] [Gain] [Q]
-> 1000Hz -----dB Q=1.00

[Freq.] 20Hz

[Amp.] -----

[Q] 0.30

:

:

:

20kHz

-----

20.00