FBT DLM26 User Manual
Page 6
![background image](/manuals/636453/6/background.png)
4.1e.
If selected a
Lo-Shelv_1
(first order Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----
[Freq.] 20Hz
[Amp.] -15.0 dB
[Q] ----
:
:
:
20kHz
+15.0 dB
----
4.1f.
If selected a
Lo-Shelv_2
(second order Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ----
[Freq.] 20Hz
[Amp.] -15.0 dB
[Q] ----
:
:
:
20kHz
+15.0 dB
----
4.1g.
If selected a
Lo-Shelv_Q
(variable Q Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00
[Freq.] 20Hz
[Amp.] -15.0 dB
[Q] 0.30
:
:
:
20kHz
+15.0 dB
20.00
4.1h.
If selected a
Lo-Pass_1
(first order Low Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----
[Freq.] 20Hz
[Amp.] -----
[Q] ----
:
:
:
20kHz
-----
----
4.1i.
If selected a
Lo-Pass_2
(second order Low Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ----
[Freq.] 20Hz
[Amp.] -----
[Q] ----
:
:
:
20kHz
-----
----
4.1l.
If selected a L
o-Pass_Q
(variable Q Low Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00
[Freq.] 20Hz
[Amp.] -----
[Q] 0.30
:
:
:
20kHz
-----
20.00
4.1m.
If selected a
Hi-Pass_1
(first order High Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----
[Freq.] 20Hz
[Amp.] -----
[Q] ----
:
:
:
20kHz
-----
----
4.1n.
If selected a
Hi-Pass_2
(second order High Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ----
[Freq.] 20Hz
[Amp.] -----
[Q] ----
:
:
:
20kHz
-----
----
4.1o.
If selected a
Hi-Pass_Q
(variable Q High Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00
[Freq.] 20Hz
[Amp.] -----
[Q] 0.30
:
:
:
20kHz
-----
20.00
4.1p.
If selected an
All-Pass_1
(first order All Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ----
[Freq.] 20Hz
[Amp.] -----
[Q] ----
:
:
:
20kHz
-----
----
4.1q.
If selected an
All-Pass_2
(second order, variable Q All Pass) filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00
[Freq.] 20Hz
[Amp.] -----
[Q] 0.30
:
:
:
20kHz
-----
20.00
4.1r.
If selected a
Band Pass
filter, then the filter can be set by
the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00
[Freq.] 20Hz
[Amp.] -15.0 dB
[Q] 0.30
:
:
:
20kHz
+15.0 dB
20.00
4.1s.
If selected a
Notch Filt
filter,
then the filter can be set by the following parameters
Input A/B
EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q=1.00
[Freq.] 20Hz
[Amp.] -----
[Q] 0.30
:
:
:
20kHz
-----
20.00