beautypg.com

FBT DLM26 User Manual

Page 55

background image

Lo Vu-Meter page – from this page it is possible to select what is shown on the Output LED
meters of the coupled channels, by using the “Param.2” or “Param.3” encoders.

The outputs' LED meters can show the Output signal LEVEL (same on both coupled channels), the
Output RMS Compressors activity (Low Compressor's Activity on the ODD channel's led) or the

Output Peak Limiters' activity (Low Limiter's Activity on the ODD channel's led).
When the Output signal Level is selected, the LED meters will show, from bottom up, the Level of

the signal:

When the RMS Low Compressor's activity is selected, the LED meters will show, from top to down,
the activity of the RMS low Compressor on the output

When the Peak Low Limiter's activity is selected, the LED meters will show, from top to down, the
activity of the Peak Low Limiter on the output

Hi Cmp sub-menu [1/2] – from this page it is possible to set the Threshold and Ratio

parameters of the RMS High Compressor.

Note: The RMS High Compressor Threshold is defined in dBu, due to the fact that with both,

Sinusoid and Squared wave testing signals, the DLM26 compressed output dBu (RMS) Level is the
same and matching the selected one.

Hi Cmp sub-menu [2/2] – from this page it is possible to set the Attack Time. Release Time

and “Knee” type of the RMS Hi Compressor.

Hi Limiter sub-menu – from this page it is possible to set the Peak High Limiter.

Note: The Peak High limiter Threshold is defined in Vp, due to the fact that with both, Sinusoid
and Squared wave testing signals, the DLM26 Peak High Limited output Vp (Peak-Peak) Level is

the same and matching the selected one.

Note1: once the desired options have been selected using the 3 encoders, they are automatically
saved as current and stored in the DLM26 system status once leaving the page.

Note2: to exit this page, push the “ESC” button.

Out-1 Name Lo Vu-Meter

-> Vu-Meter = Limiter Act

Out-1 Name Lo Vu-Meter

-> Vu-Meter = Level

Out-1 Name Lo Vu-Meter

-> Vu-Meter = RMS Cmp Act