Specifications

|

25

Model 94430 Series Current Probe

M

ODEL

94430

S

ERIES

P

HYSICAL

S

PECIFICATIONS

Window Diameter:

1.91 cm

0.75 in

Outside Diameter:

5.72 cm

2.25 in

Width:

2.54 cm

1.0 in

Output Connector:

Type BNC

Weight:

0.18 kg

6.5 oz

Impedance:

50

M

ODEL

94430

S

ERIES

E

LECTRICAL

S

PECIFICATIONS

94430-1 / 94430-1L

Frequency Range

(L Models 20 Hz):

10 kHz–250 MHz

Transfer Impedance

(Nominal):

• 6

Ω ± 2 dB @ 10 MHz–250 MHz

• 3

Ω ± 2 dB @ 1 MHz

• 0.6

Ω ± 3 dB @ 100 kHz

• 0.1

Ω ± 3 dB @ 10 kHz

RF Current Range

(RF CW):

16 amps

RF Current Range

(Pulse):

70 amps

Maximum Power

Current

(DC–400 Hz):

200 amps