ETS-Lindgren 94606-6 Current Probe User Manual
Page 25

Specifications
|
25
Model 94430 Series Current Probe
M
ODEL
94430
S
ERIES
P
HYSICAL
S
PECIFICATIONS
Window Diameter:
1.91 cm
0.75 in
Outside Diameter:
5.72 cm
2.25 in
Width:
2.54 cm
1.0 in
Output Connector:
Type BNC
Weight:
0.18 kg
6.5 oz
Impedance:
50
Ω
M
ODEL
94430
S
ERIES
E
LECTRICAL
S
PECIFICATIONS
94430-1 / 94430-1L
Frequency Range
(L Models 20 Hz):
10 kHz–250 MHz
Transfer Impedance
(Nominal):
• 6
Ω ± 2 dB @ 10 MHz–250 MHz
• 3
Ω ± 2 dB @ 1 MHz
• 0.6
Ω ± 3 dB @ 100 kHz
• 0.1
Ω ± 3 dB @ 10 kHz
RF Current Range
(RF CW):
16 amps
RF Current Range
(Pulse):
70 amps
Maximum Power
Current
(DC–400 Hz):
200 amps