ETS-Lindgren 94606-6 Current Probe User Manual
Page 24
24
|
Specifications
94111-1 / 94111-1L
94111-2
Maximum Power
Current
(DC–400 Hz):
200 amps
200 amps
Maximum Power
Voltage:
No limitation; subject to adequate
conductor insulation
Sensitivity Under
Rated Load:
0.2 microampere with
1 microvolt sensitivity
receiver and 5 ohms
transfer impedance
1 microampere with
1 microvolt sensitivity
receiver and 1 ohm
transfer impedance
M
ODEL
94111
S
ERIES
P
ULSE
P
OWER
L
IMITS
94111-1 / 94111-1L
94111-2
RF Current Range
(Pulse):
50 amps for duty cycle less
than 0.4
Pulse signals with peak
currents to 200 amps can
be measured if the pulse
duty cycle does not
exceed:
• (10 amps I
P
) 0.06 Duty
• (50 amps I
P
)
0.0024 Duty
• (100 amps I
P
)
0.0006 Duty
• (200 amps I
P
)
0.00015 Duty
Maximum Power
Current
(L Models Only):
(DC to 1500 Hz) 300 amps
When both signal and
power currents are high,
their sum should not
exceed the given limits
NA