Detex AO19-1 Push User Manual
Page 7
16-1/2”
104850 Page 7
Door Foot Location - for Push Units
The center of the door foot should be located 16 1/2" from the hinge side of the door panel and
should be level when the rod is inserted in the sleeve attached to the arm.
Mark the door for the door foot holes and secure the foot to the door with the supplied screws.
Turn the 3-way toggle switch to the “HOLD” position.
With the door at full open, hold the steel rod next to the rod connector at the end of the arm, mark
and cut the rod so it will fit into the rod connector. The rod length should allow the rod to be secured
with both set screws and allow for adjustment of the door opening. Insert the rod into the connector
with the door in full open position and adjust until the desired opening is achieved. Tighten the set
screws to secure the rod.
Bent Arm -
P/N-12731-X
Rod Connector -
P/N-12736-X
Door Foot -
P/N-12735-X
Secure with
screws provided
Swing Arm Rod -
P/N-12734-X
Mark and Cut
3/8-24 Acorn Nut -
P/N-12741-X
Female Rod Ends -
P/N-12738-X