Ea" switch options, Figure 2, Figure 3 – Detex Exit Switch - Weatherized User Manual

Page 3: Figure 1, Standard), Battery connector, Ea wiring detail, P1 detail, Protect wires to avoid pinching, Ea shown)

background image

(Standard)

Contacts rated at 1.0A @ 30VDC or 0.5A @ 125VAC

Battery Connector

(P1 wire usage)

Table 4

Remote Signal

Pin 2
Pin 3

Pin 1

Yellow

Green

Normally Open

Normally Closed

Common

Brown

EA wiring detail

Figure 2.

N.O. contact

N.O. contact

Violet

----

Violet

1

2

3

----

Pin 5
Pin 6

Pin 4

Remote Bypass

Figure 3.

P1 detail

4

5

6

Protect wires to avoid pinching

Dis Lo Bat switch set to "OFF"

P1

J1

(EA shown)

P2

J2

Extended bypass is enabled.

The Device flashes red or green LED every 15 seconds.

The Device gives no indication of armed or disarmed status.

Red indicates armed status and green indicates disarmed.

Auto Rearming Feature Setting

Alarm sounds until turned off with key.

Status Description

Switch selections must be made before applying power or installing battery (See Figure 1)

Note: AC power must be applied for switch to operate

The device flashes one red LED and one beep about every 45 seconds

The device gives no indication of battery being low.

Status Description

Alarm will automatically rearm after 2 minutes.

Unit sounds alarm for 2 minutes after bar is released.

Off *

Auto rearm

On

On *

Disable

Low Battery

On

Off *

Disable

Off

Indicator

Status

Table 3

See Table 1

STATUS INDICATOR switch set to "OFF"
Disable AUTO REARM switch set to "ON"

* Factory default settings:

See

Table 2

Table 2

Table 3

Dis Lo Bat

D

is

ab

le

ON

O

N

S

TA

TU

S

ON

IN

D

IC

AT

O

R

A

U

TO

R

EA

R

M

Selector switches detail

See

"EA" SWITCH OPTIONS

Table 1

Figure 1.

12/24 V AC/DC External Supply

(sold separately)

(24V AC/DC Optional)

Bypass/Remote Signal

(Optional)

104873 Page 3