beautypg.com

Attwood Turbo 3000 In-Line Blowers User Manual

Turbo in-line bilge blowers, Warning

background image

ABYC H2/IS0 9097 MARINE BLOWER PERFORMANCE SPECIFICATIONS

ATTWOOD BILGE BLOWERS LIMITED WARRANTY:

A

TTWOOD CORPORA

TION, 1016 North Monroe, Lowell, Michigan 49331, (‘Attwood’)

warrants to the original consumer purchaser that this

Attwood Bilge Blowers, numbers

1731 and 1747 will be free from defects in materials and workmanship under normal

use and service for a period of three (3) years.

These models are not intended for use

in applications which allow direct contact with water or other liquids. Evidence of such

product damage voids this warranty

. Attwood also warrants the

Attwood Bilge Blowers,

numbers 1733 and 1749 will be free from defects in materials and workmanship under

normal use and service for a period of three (3) years from the date of original consumer

purchase.

This warranty does not extend to any batteries or fuses used with the blower

.

This limited warranty is not applicable if the bilge blower has been damaged by accident,

improper installation, unreasonable use, lack of proper maintenance, unauthorized repairs

or modi

fi cations, or other causes not arising out of defects in materials or workmanship.

Attwood’

s obligations under this warranty are limited to repair of the product at

Attwood’

s

plant or replacement of the product at

Attwood’

s option and at

Attwood’

s expense.

Any

expenses involved in the removal, reinstallation, or transportation of the product are not

covered by this warranty

. The

product must be returned to

Attwood’

s plant at the address indicated above postage

prepaid, with proof of original purchase including date. If

Attwood is unable to replace the

bilge blower and repair is not commercially practicable or cannot be timely made, or if the

original consumer purchaser is willing to accept a refund in lieu of repair or replacement,

Attwood may refund the purchase price, less an amount for depreciation.

The acceptance

by

Attwood of any product returned or any refund provided by

Attwood shall not be deemed

an admission that the product is defective or in violation of any warranty

.

THIS W

ARRANTY

IS

A

TTWOOD’S ONL

Y

EXPRESS W

ARRANTY

OF

THIS PRODUCT

.

NO IMPLIED W

ARRANTY

SHALL

EXTEND BEYOND

THREE (3)

YEARS FROM

THE

DA

TE OF ORIGINAL

CONSUMER PURCHASE.

A

TTWOOD SHALL

NOT

BE LIABLE

FOR

ANY

DAMAGES FOR LOSS OF USE OF

THIS PRODUCT

, NOR FOR

ANY

OTHER

INCIDENT

AL

OR CONSEQUENTIAL

DAMAGES, COSTS OR EXPENSES.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion

or limitation of incidental or consequential damages, so the above limitations and

exclusions may not apply to you.

This warranty gives you speci

fi c legal rights and you may

have other rights which may vary from state to state.

1.5

1.0

0.5

0

150

100

50

0

150

100

50

2.5

-8,500

3.0

-9,500

3.5

-10,500

1.5

1.0

0.5

2.5

-8,500

3.0

-9,500

3.5

-10,500

1.5

0.5

0

150

250

0-

6,800

1.0

2.0

2.5

3.0

1.5

0.5

1.0

2.0

100

50

200

0

150

250

100

50

200

2.0

-7,500

2.5

1.0

-7,150

0-

6,800

2.0

-8,600

1.0

-7,700

TURBO IN-LINE BILGE BLOWERS

INSTALLATION INSTRUCTIONS

09/01

69465 Rev. A

SAVE THESE INSTRUCTIONS

Model No.

Speci

fi cation

Voltage

CFM

Open Flow

CFM

In System

Amp

Draw

Fuse

Size

Turbo 3000

13.6

145

100

3.1

4-amp

Turbo 4000

13.6

230

125

2.9

5-amp

Turbo 4000 (24V)

27.2

230

125

2.0

3-amp

*In system = 3 ft. of duct with one 90° bend, a collector box and louvered vent on

discharge side of blower.

Blower models 1733, 1734, 1743, 1749 and 1751 (24V, 4

") are water resistant. Models

1731, 1741 and 1747 are not water-resistant. All Turbo blowers are ignition protected.

Connect to 12-volt D.C. systems only (24 volt for Model 1751).

WARNING:

To prevent personal injury, always disconnect electrical connection when

installing or servicing this product.

Always use a fuse with amperage rating speci

fi

ed for the blower model.

Before starting engines, operate blower a minimum of four minutes, then check

engine compartment for fume odor. Operate blowers when motoring below 5 miles

per hour.

Do not operate in area of high heat over 160° F (71°C).

Do not operate while refueling.

MOUNTING INSTRUCTIONS

Select a

fl at mounting surface high above the bilge, clear of moisture from spray

1.

or

deck wash.

Position blower with the

fl ow arrow pointing toward exhaust vent. Also, mount

2.

blower

at an angle to prevent moisture build-up. See Figure 1.

Mark mounting holes. Drill holes for #10 screws and secure unit in place using

3.

stainless steel screws. Do not over tighten screws.

Twist duct hose over exhaust and intake openings on blower. Ensure the retainer

4.

tabs engage corrugated rings of hose.

Install tie strap or hose clamp on the hose. Position the strap or clamp around

5.

blower

housing, beyond the tabs. Tighten the strap. Do not overtighten straps or clamps.

Route intake end of hose directly to the lowest point in the bilge, with as few bends

6.

as possible. The hose pick-up must not be low enough to become submerged in

bilge water. See Figure 1.

Route exhaust end of hose directly to vent or vent collector box, with as few bends

7.

as possible. Connect hose securely to vent. See Figure 1.

Figure 1

Figure 1

Abbildung 1

Vertical Transom Mount
A.

Horizontal Transom Mount
B.

Deck Mount
C.

A. Senkrechte Montage am Heckspiegel

B. Horizontale Montage am Heckspiegel

C. Montage an Deck

Figure 1

Figur 1

A. Montage de tableau vertical

B. Montage de tableau horizontal

C. Montage sur le pont

A. vertikalt akterspegelfäste

B. horisontellt akterspegelfäste

C. däcksfäste

Figura 1

A. Montaje de bovedilla vertical

B. Montaje de bovedilla horizontal

C. Montaje de la cubierta

WIRING INSTRUCTIONS

Fuse holder must be installed within 72” (183cm) of the battery (+) terminal. See

1.

table

for proper fuse size. Connect ON/OFF switch into the circuit and mount it in the dash

control panel.

If your boat is not equipped with a blower “WARNING” label like the one shown

2.

below,

please contact our customer service department for a free label — Part No. 9158WR.

Figure 2

Figure 2

Abbildung 2

Flow Arrow
A.

Bilge Blower
B.

Yellow
C.

Black
D.

Wire Connectors If Required
E.

Switch
F.

Fuse
G.

72” (183 cm) max
H.

Battery
I.

Durch

fl usspfeil

A.

Bilgenlüfter
B.

Gelb
C.

Schwarz
D.

Drahtverbinder, falls erforderlich
E.

Schalter
F.

Sicherung
G.

Maximal 183 cm (72 Zoll)
H.

Akku
I.

Figure 2

Figur 2

Flèche de débit
A.

Ventilateur de cale
B.

Jaune
C.

Noir
D.

Connecteurs de

fi l si requis

E.

Interrupteur
F.

Fusible
G.

183 cm maximum
H.

Batterie
I.

strömningspil
A.

slagvattens

fl äkt

B.

gul
C.

svart
D.

kabelkontakter vid behov
E.

strömbrytare
F.

säkring
G.

maximalt 72 tum (183 cm)
H.

batteri
I.

Figura 2

Flecha de

fl ujo

A.

Soplador de sentina
B.

Amarillo
C.

Negro
D.

Conectores del cable si se requieren
E.

Interruptor
F.

Fusible
G.

1,8 m como máx.
H.

Batería
I.

© 2009

Attwood Corporation

1016 N. Monroe Street, Lowell, MI 49331-0260 www

.attwoodmarine.com

AB

C

A

B

C

D

E

G

H

3"

Blowers (1731 & 1733)

Performance at 12 VDC

4"

Blowers

(1741, 1743, 1747 & 1749)

Performance at 12 VDC

3"

Blowers (1731 & 1733)

Performance at 13.6 VDC

4”

Blowers

(1741, 1743, 1747 & 1749)

Performance at 13.6 VDC

I

WARNING

GASOLINE VAPORS CAN EXPLODE

BEFORE STARTING ENGINE:

OPERATE BLOWER FOR 4 MINUTES

CHECK ENGINE COMP'T FOR GAS OR VAPORS RUN BLOWER WHEN BELOW CRUISING SPEED

STATIC PRESSURE (IN-H20)

AIR FLOW (CFM)

AIR FLOW (CFM)

Flow

Flow

Flow

Flow

Speed

Speed

Speed

Speed

AMPS

AMPS

AMPS

AMPS

AIR FLOW (CFM)

AIR FLOW (CFM)

STATIC PRESSURE (IN-H20)

STATIC PRESSURE (IN-H20)

STATIC PRESSURE (IN-H20)

AMPS (DC)

SPEED (RPM)

SPEED (RPM)

SPEED (RPM)

SPEED (RPM)

AMPS (DC)

AMPS (DC)

AMPS (DC)