beautypg.com

A.3.2 tpim-f3 for single mode fiber – Cabletron Systems STHI User Manual

Page 71

background image

Fiber Optic TPIM Specifications

Page A-4

A.3.2

TPIM-F3 for Single Mode Fiber

The TPIM-F3 connector supports Single Mode Fiber Optic cabling.

Transmitter Power decreases as temperatures rise. Use the Output Power
Coefficient (-0.15 dBm) to calculate increased or decreased power output
for the operating environment. For example, the typical power output at
25

°

C is -16.4 dBm. For a 4

°

C temperature increase, multiply the typical

coefficient (-0.15 dBm) by four and add the result to typical output power:
(4 x -0.15 dBm + -16.4 = -17.0).

Figure A-4. Transmitter Power Levels

Table A-3. TPIM-F3 Specifications

Parameter

Typical

Minimum

Maximum

Transmitter

Peak Wave Length

1300 nm

1270 nm

1330 nm

Spectral Width

60 nm

100 nm

Rise Time

3.0 nsec

2.7 nsec

5.0 nsec

Receive

Sensitivity

dBm

Less Power

More Power

-40

-35

-30

-25

-20

-15

-10

-5

0

Maximum

Receive

Input Power

Transmitter Power*

(At 25

°

C into

8.3/125

µ

m fiber)

Minimum Sensitivity (-30.0)

Typical Sensitivity (-31.0)

Maximum Sensitivity (-36.0)

Maximum Receive Input (-6.99)

Typical Receive Input (-7.5)

Minimum Receive Input (-9.72)

Maximum Transmit Power (-12.0)

Typical Transmit Power (-15.5)

Minimum Transmit Power (-21.0)

* Transmit Power Typical Power Minimum Power Maximum Power
Coefficient
(See Note Below)-0.15dBm/

°

C -0.12 dBm/

°

C-0.18 dBm/

°

C