beautypg.com

3 the system level screen, 1 system date and system time, 2 ip address – Cabletron Systems STHI User Manual

Page 43: The system level screen -8 5.3.1, System date and system time -8, Ip address -8

background image

The System Level Screen

Page 5-8

5.3 The System Level Screen

Access the System Level screen (Figure 5-4) from the Device Setup menu.

Figure 5-4. System Level Screen

5.3.1

System Date and System Time

Use these fields to set the correct date and time.

Type the date into the field in a MM/DD/YY format for the date, and
HH:MM:SS for the time. If the format entered is invalid, the message
“Invalid Date” or “Invalid Time” appears and the edit is rejected.

5.3.2

IP Address

Use this field to set the host Internet Protocol (IP) address for the STHI.

If the IP Address is changed, the STHI will execute a soft-reset after

SAVE

is invoked to re-initialize all affected parameters.

Only a user with Super-User access can change the device’s
IP address. See Section 5.4 for information about
Super-User access.

STHI LOCAL MANAGEMENT Flash Image Version: 1.00.00

SYSTEM LEVEL

System Date:

06/15/10

System Time:

13:08:00

IP Address Subnet Mask
SNMP Agent

134.141.143.141 255.255.0.0

Enable IP Address Discovery: [

YES

] State: [SEEKING ]

Retry Interval (0001-9999 Mins):

0015

Enable Beacon Recovery: [

YES

]

Number of Retries (000-100, 999=infinite):

004

Retry Interval (000-999 Secs):

021

FNB MAC Address - Physical: 00-00-B8-00-00-00
FNB MAC Address - Locally Administered:

00-00-B8-E8-A5-B1

SAVE RETURN

TIP