Operational mode – Cabletron Systems STHI User Manual
Page 54

The Chassis Status View Screen
Page 5-19
OPERATIONAL Mode
3
In
OPERATIONAL
mode (Figure 5-7), the Chassis Status View screen is
read-only, displaying the operational status of all ports throughout the
stack. The possible states for Ring ports differ from those for STN TCUs.
Figure 5-10. Chassis Status View Screen in
OPERATIONAL
Mode
Each Ring port (TPIM port or Ring Out TCU) may be listed as:
ACT
The enabled ring port has opened its connection, having
detected data on the line. The attached device is inserted into
a ring.
WRP
The port is in the wrap state. Either the port is disabled, or is
not detecting data and is remaining closed.
Each station TCU port may be listed as:
INS
The port is enabled and the attached device is applying
phantom current. The device is inserted into the ring.
ENB
The port is enabled but no phantom current is present.
BYP
The port is disabled (see
ADMINISTRATIVE
mode) and no
phantom current is present.
LNK
An attached device is applying phantom current, but the port
is disabled, preventing insertion of the attached device into
the ring.
CHASSIS STATUS VIEW ( OPERATIONAL )
5 4 3 2 1
STH24 STH24 STH24 STH24 STHI24
|---> <---> <-B-> <---> <---|
16Mb/s 16Mb/s 16Mb/s 16Mb/s 16Mb/s
1 BYP 1 BYP 1 BYP 1 BYP 1 INS
2 INS 2 INS 2 LNK 2 BYP 2 INS
3 ENB 3 LNK 3 ENB 3 ENB 3 INS
4 INS 4 LNK 4 INS 4 LNK 4 INS
5 LNK 5 INS 5 INS 5 LNK 5 INS
6 INS 6 INS 6 ENB 6 LNK 6 ENB
7 ENB 7 ENB 7 ENB 7 ENB 7 ENB
8 ENB 8 ENB 8 ENB 8 ENB 8 ENB
9 INS 9 INS 9 ENB 9 INS 9 ENB
10 INS 10 INS 10 INS 10 INS 10 BYP
11 INS 11 INS 11 INS 11 INS 11 LNK
12 ENB 12 ENB 12 ENB 12 INS 12 ENB
NEXT [ OPERATIONAL ] [ REFRESH 3sec ] RETURN
STHI LOCAL MANAGEMENT Flash Image Version: 1.00.00