beautypg.com

A.3.1 tpim-f2 for multimode fiber – Cabletron Systems STHI User Manual

Page 70

background image

Fiber Optic TPIM Specifications

Page A-3

Figure A-3. The TPIM-F2 Faceplate.

A.3.1

TPIM-F2 for Multimode Fiber

The TPIM-F2 connector supports Multimode Fiber Optic Cabling.

The transmitter power and receive sensitivity levels given in Table A-2 are
Peak Power Levels after optical overshoot. A Peak Power Meter must be
used to correctly compare the given values to those measured on any
particular port. If Power Levels are being measured with an Average
Power Meter, then 3 dBm must be added to the measurement to correctly
compare those measured values to the values listed in Table A-2 (i.e. -30.5
dBm peak=-33.5 dBm average).

Table A-2. TPIM-F2 Specifications.

Parameter

Typical

Value

Worst Case

Worst Case

Budget

Typical

Budget

Receive

Sensitivity

-30.5 dBm

-28.0 dBm

Peak Input

Power

-7.6 dBm

-8.2 dBm

Transmitter Power:

50/125

µ

m

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125

µ

m

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140

µ

m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate: Better than 10

-10

TPIM-F2

LNK

RX

TX