6.
Push the ejectors on the RAID hardware key connector down and outward to allow the key to be inserted into the connector (see
).
7.
See
Figure A
-3
to locate the RAID hardware key on the system board.
8.
Press on the hardware key with your thumbs while pulling up on the ejectors with your index fingers to lock the hardware key into the connector.
Figure 7-4. Installing the RAID Hardware Key
9.
Connect the battery cable to the RAID battery cable connector on the system board.
See
Figure A
-3
to locate the RAID battery cable connector on the system board.
10.
Hook the retention tab on the bottom of the battery into the slot in the chassis side wall, and then snap the battery release clip into place (see
).
Figure 7-5. Removing and Installing the RAID Battery
11.
Replace the cover (see "
Replacing the Cover
" in "Troubleshooting Your System").
12.
Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
13.
Enter the System Setup program and verify that the setting for the SCSI controller has changed to reflect the presence of the RAID hardware (see