Dell PowerEdge M605 User Manual
Page 73

About Your System
73
No boot device
available.
Faulty or missing diskette
drive, optical drive, or hard
drive.
Check the Integrated
Devices configuration
settings in the System Setup
program and ensure that the
controller for the boot
device is enabled. See "Using
the System Setup Program"
on page 79. Ensure that the
controller for the boot
device is enabled.
If the problem persists,
replace the drive. See "Hard
Drives" on page 142.
No boot sector on
hard-disk drive.
An operating system is not
on the hard drive.
Check the hard-drive
configuration settings in the
System Setup program. See
"Using the System Setup
Program" on page 79.
No timer tick
interrupt.
Faulty blade board.
See "Getting Help" on
page 217.
Not a boot
diskette.
Not a bootable diskette.
Use a bootable diskette.
PCI BIOS failed to
install.
Faulty or improperly
installed mezzanine card.
Reseat the mezzanine card.
See "I/O Module Mezzanine
Cards" on page 123. If the
problem persists, see
"Getting Help" on page 217.
Plug & Play
Configuration
Error.
Error encountered in
initializing PCI device;
faulty blade board.
Set the NVRAM_CLR
jumper to "on" and reboot
the blade. See
Figure 7-4 for the jumper
location.
Check for a BIOS update. If
the problem persists, see
"Getting Help" on page 217.
Table 1-18.
Blade Messages (continued)
Message
Causes
Corrective Actions