Dell PowerEdge M605 User Manual
Page 44

44
About Your System
•
Slot Mezz2_Fabric_B and slot Mezz4_Fabric_B support Fabric B. If a card
is installed in both slots, both cards must be identical. They must also
match the fabric type of the I/O modules installed in I/O module bays B1
and B2.
PowerEdge M600 and M605
The half-height PowerEdge M600 and M605 blades support two mezzanine
cards:
•
Mezzanine card slot C supports Fabric C. This card must match the fabric
type of I/O modules installed in I/O module bays C1 and C2.
•
Mezzanine card slot B supports Fabric B. This card must match the fabric
type of I/O modules installed in I/O module bays B1 and B2.
See "I/O Module Mezzanine Cards" on page 123 for more information on
mezzanine cards.
Table 1-11 shows various supported combinations of mezzanine cards and I/O
modules.
Table 1-11.
Supported I/O Module Configurations
Fabric A
Fabric B
Mezzanine
Card
Fabric C
Mezzanine
Card
I/O Bay A1,
A2
I/O Bay B1,
B2
I/O Bay C1,
C2
Standard
Integrated
LOM NIC
none
none
Ethernet
switch
module or
pass-through
module
none
none
Standard
Integrated
LOM NIC
Ethernet
mezzanine
card
none
Ethernet
switch
module or
pass-through
module
Ethernet
switch
module or
pass-through
module
none
Standard
Integrated
LOM NIC
none
Infiniband
mezzanine
card
Ethernet
switch
module or
pass-through
module
none
Infiniband
switch
module