Dell PowerEdge M605 User Manual
Page 70

70
About Your System
Error: Memory
failure detected.
Memory size
reduced. Replace
the faulty DIMM as
soon as possible.
Faulty or improperly
seated memory modules.
See "Troubleshooting Blade
Memory" on page 191.
Error programming
flexAddress (MAC)
for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
Error programming
flexAddress (iSCSI
MAC) for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
Error resetting
NIC after
programming
flexAddress for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
FBD training
error: The
following branch
has been disabled:
Branch
x
.
The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.
Ensure that only Dell
qualified memory is used.
Dell recommends
purchasing memory upgrade
kits directly from
http://www.dell.com or your
Dell sales agent to ensure
compatibility.
Gate A20 failure.
Faulty keyboard controller
(faulty blade board).
See "Getting Help" on
page 217.
General failure.
Operating system
corrupted or improperly
installed.
Reinstall the operating
system.
Table 1-18.
Blade Messages (continued)
Message
Causes
Corrective Actions