beautypg.com

Raid level 10 – Dell Precision T7400 (Late 2007) User Manual

Page 43

background image

Advanced Features

43

RAID Level 10

NOTE:

RAID levels 5 and 10 are only available via an optional PCI Express RAID

controller card.

RAID level 10 uses a combination of striping and mirroring methods. It

requires four drives. The drives are broken up into mirroring pairs and then

the data that is written to the RAID configuration is striped across all four

drives. Data can be accessed quickly, due to the striping of data, however each

piece of data is duplicated on another drive, for redundancy purposes.

If a drive failure occurs, subsequent read and write operations are directed to

the other surviving drives. A replacement drive can then be rebuilt using the

data from the surviving drives. Also, because data is duplicated on the primary

and additional drives, four 120-GB RAID level 1 drives collectively have a

maximum of 240-GB on which to store data.

hard drive 1

segment 1
segment 2
segment 3

hard drives 2, 3, and 4

segment 4
segment 5
segment 6

segment 1 striped across 4 drives
segment 2 striped across 4 drives
segment 3 striped across 4 drives
segment 4 striped across 4 drives
segment 5 striped across 4 drives
segment 6 striped across 4 drives

SATA RAID

configured for

RAID level 10