Invalid configuration information - please
run SETUP program

The system configuration information
does not match the hardware
configuration.

Enter

system setup

and correct the

system configuration information.

Keyboard clock line failure

Keyboard controller failure

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

A cable or connector may be loose,
or the keyboard or keyboard/mouse
controller may be faulty.

See "

Keyboard Problems

."

Memory address line failure at address,

read value expecting value

One or more DIMMs may be faulty or
improperly seated.

See "

System Memory Problems

."

Memory allocation error

The software you are attempting to
run is conflicting with the operating
system or another application
program or utility.

Turn off the computer, wait 30 seconds,
and then turn it on. Try to run the program
again. If the problem persists, contact the
software company.

Memory data line failure at address, read

value expecting value


Memory double word logic failure at
address, read value expecting value


Memory odd/even logic failure at address,

read value expecting value


Memory write/read failure at address, read

value expecting value

One or more DIMMs may be faulty or
improperly seated.

See "

System Memory Problems

."

Memory size in CMOS invalid

The amount of memory recorded in
the system configuration information
does not match the memory installed
in the computer.

Reboot the computer. If the error appears
again, see "

Getting Help

" for instructions

on obtaining technical assistance.

Memory tests terminated by keystroke

The memory test was not completed. Rerun the memory test.

No boot device available

The computer cannot find the
diskette or hard drive.

Enter

system setup

, check the system

configuration information for the diskette
and hard drive, and, if necessary, correct
the information.

No boot sector on hard-disk drive

The system configuration information
in system setup may be incorrect, or
the operating system may be
corrupted.

Enter

system setup

, check the system

configuration information for the hard
drive, and if necessary, correct the
information.

If the problem persists, reinstall your
operating system. See the
documentation that came with your
operating system.

No timer tick interrupt

A chip on the system board might be
malfunctioning.

Run the System Board Devices tests in
the

Dell Diagnostics

.

Non-system disk or disk error

The diskette in drive A or your hard
drive does not have a bootable
operating system installed on it.

A nonbootable diskette is in drive A.
Either replace the diskette with one that
has a bootable operating system, or
remove the diskette from drive A and
restart the computer.

Not a boot diskette

There is no operating system on the
diskette.

Boot the computer with a diskette that
contains an operating system.

Plug and Play Configuration Error

The system has encountered a
problem in trying to configure one or
more expansion cards.

Turn your system off and unplug it.
Remove all but one of the cards. Plug in
your system and reboot it. If the problem
persists, the expansion card may be
malfunctioning. If the message does not
reappear, turn off the power and reinsert
one of the other cards. Repeat this
process until you identify the
malfunctioning card.

Read fault

Requested sector not found

The operating system cannot read
from the diskette or hard drive.

The system could not find a particular

See "

Drive Problems

."