25

CAUTION:

A power supply/cooling fan module can be removed from a powered-

on enclosure for a maximum period of no more than 5 minutes. Beyond that time,
the enclosure may automatically shut down to prevent damage to the enclosure
and/or enclosure components.

A power supply/cooling fan module can be replaced without powering down
the enclosure. For information on removing and replacing the modules, see
"Removing and Installing the Power Supply/Cooling Fan Module" on page 64.

Figure 1-7 shows the power supply/cooling fan module features and LED
indicators. Table 1-5 lists the LED indicator descriptions.

Figure 1-7.

Power Supply and Cooling Fan Module LED Features and Indicators

1

DC power LED

2

Power supply/cooling fan
fault LED

3

AC power LED

4

cooling fans (2)

5

on/off switch

6

AC power connector

1

4

5

6

2

3