beautypg.com

Connunitstate 1.3.6.1.3.94.1.6.1.5, Connunitstatus 1.3.6.1.3.94.1.6.1.6 – Dell POWEREDGE M1000E User Manual

Page 257

background image

Fabric OS MIB Reference

239

53-1001768-01

connUnitState 1.3.6.1.3.94.1.6.1.5

8

NOTE

The ConnUnitNumports will not count the GE ports present on FC4-16IP blade.

The maximum number of supported ports are as follows.

Brocade 300

24 ports

Brocade 4100

32 ports

Brocade 4900

64 ports

Brocade 5000

32 ports

Brocade 5100

40 ports

Brocade 5300

80 ports

Brocade 7500 or 7500E

32 ports

Brocade 7600

16 ports

Brocade 7800 Extension Switch

24 ports

Brocade 8000

32 ports

Brocade Encryption Switch

32 ports

Brocade DCX

576 ports

Brocade DCX-4S

288 ports

Brocade 48000

384 ports

connUnitState 1.3.6.1.3.94.1.6.1.5

Overall state of the connectivity unit.

Values

Possible values are:

unknown (1)

online (2) Set the state to online.

offline (3) Set the state to offline.

Mapped as follows:

switchState(ONLINE) 2 (online)

switchState(not ONLINE) 3 (offline, testing, faulty)

connUnitStatus 1.3.6.1.3.94.1.6.1.6

Overall status of the connectivity unit. This switch status is based on the most severe status of
contributors like Power supplies, Temperatures, Fans, WWN servers, Standby CP, Blades, Flash,
Marginal ports, Faulty ports, Missing SFPs, and so on. switchStatusPolicyShow command displays
the policy parameters that determines the overall switch status.

Values

Possible values are:

unknown (1) - Unknown

unused (2) - Unmonitored