beautypg.com

Dell PowerEdge 800 User Manual

Page 22

background image

Message

Causes

Corrective Actions

Amount of available memory limited to

256MB!

OS Install Mode is enabled
in the System Setup program.

Disable OS Install Mode in the System Setup program. See "Using the System
Setup Program" in your User's Guide.

Attempting to update Remote

Configuration. Please wait....

Remote Configuration is in
progress.

Wait until the process is complete.

BIOS Update Attempt Failed

BIOS remote update failed.

Retry update.

Caution! NVRAM_CLR jumper is installed

on system board.

NVRAM_CLR jumper is
installed.

Remove the NVRAM_CLR jumper. See

Figure A

-2

for the jumper location.

CD-ROM drive not found

Improperly connected or
missing optical drive.

If no optical drive is installed, disable the IDE controller. See "Using the System
Setup Program" in your User's Guide.

If an optical drive is installed, see "

Troubleshooting an Optical Drive

" in

"Troubleshooting Your System."

Decreasing available memory

Faulty or improperly installed
memory modules.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

" in "Troubleshooting Your System."

Diskette drive 0 seek failure

Incorrect configuration
settings in System Setup
program.

Run the System Setup program to correct the settings. See "Using the System
Setup Program" in your User's Guide.

Faulty or improperly installed
diskette, loose diskette drive
or optical drive interface
cable, or loose power cable.

Replace the diskette. Ensure that the diskette drive and optical drive cables
are properly connected. See "

Troubleshooting a Diskette Drive

" and

"

Troubleshooting an Optical Drive

" in "Troubleshooting Your System."

Diskette read failure

Faulty or improperly inserted
diskette.

Replace the diskette.

Diskette subsystem reset failed

Faulty diskette drive or
optical drive controller.

Ensure that the diskette drive and optical drive cables are properly connected.
See "

Troubleshooting a Diskette Drive

" and "

Troubleshooting an Optical Drive

"

in "Troubleshooting Your System." If the problem persists, see "

Getting Help

."

Drive not ready

Diskette missing or
improperly inserted in
diskette drive.

Reinsert or replace the diskette.

Dual rank DIMMs are not supported in the

following memory sockets in this memory

configuration.

Invalid memory configuration. Correct the memory configuration. See "

General Memory Module Installation

Guidelines

" in "Installing System Components."

Error: Incorrect memory configuration.

Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B match

identically in size, speed, and rank.

An unmatched pair of memory
modules is installed.

Install a matched pair of memory modules, or remove the memory module in
socket DIMM1_B. See "

General Memory Module Installation Guidelines

" in

"Installing System Components."

Error: Remote Access Card initialization

failure.

Faulty or improperly installed
RAC.

Ensure that the RAC is properly installed. See "

Troubleshooting Expansion

Cards

" in "Troubleshooting Your System," or "

Installing a RAC Card

" in

"Installing System Components."

 

Error 8602: Auxiliary device failure.

Verify that the keyboard and mouse are

securely attached to correct connectors.

Loose or improperly
connected mouse or
keyboard cable; faulty mouse
or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

."

General failure

Operating system corrupted
or improperly installed.

Reinstall the operating system.

IDE Primary drive 1 not found

Improperly connected or
missing optical drive or tape
backup unit.

Ensure that the drive cables are properly connected. See "

Troubleshooting

Your System

" for the appropriate drive installed in your system.

If no drive is installed, disable the IDE controller. See "Using the System Setup
Program" in your User's Guide.

Keyboard controller failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists,
replace the keyboard. If the problem persists, see "

Getting Help

."

 

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

 

 

Faulty system board. See "

Getting Help

."

Manufacturing mode detected

System is incorrectly
configured.

After the message appears during system boot, press to turn off
manufacturing mode.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address,

read value expecting value

Faulty or improperly installed
memory modules, or faulty
system board.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

" in "Troubleshooting Your System." If the problem persists, see

"

Getting Help

."

Memory tests terminated by keystroke

The spacebar was pressed

Information only.