beautypg.com

Scsi hard-drive indicator codes – Dell PowerEdge 800 User Manual

Page 19

background image

 

SCSI Hard-Drive Indicator Codes

If an optional SCSI RAID controller is installed in the system, two indicators on each of the hard-drive carriers provide information on the status of the SCSI
hard drives. See

Figure 2

-3

and

Table 2

-3

. The SCSI backplane firmware controls the drive power

-on/fault indicator.

 

Figure 2-3. SCSI Hard-Drive Indicators

Table 2

-3

lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard drive fails, the "drive

failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive ready for
insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by the "drive online"
pattern.

 

Table 2-3. Hard-Drive Indicator Patterns 

NOTE:

If a RAID controller is not installed, only the "drive online" indicator pattern appears. The drive-activity indicator also blinks when the drive is

being accessed.

 

Condition

 

Indicator Pattern

Identify drive

The green power-on/fault indicator blinks four times per second.

Drive being prepared for removal

The green power-on/fault indicator blinks two times per second.

Drive ready for insertion or removal Both drive indicators are off.

Drive being prepared for operation The green power-on/fault indicator is on.