Elster/kent helix & domestic meters – ADS Environmental Services PrimeWorks QR 775018 A0 User Manual
Page 82

ADS PrimeWorks User Manual
76
Elster/Kent Helix & Domestic Meters
Meter
PU10/LRP
PU100/HRP
(mm)
FCAL
Helix 2000
40-80
10
1
100-300
100
10
Helix 3000
40-80
10
1
100
10
1
150
100
10
Master 2000
40-50
1
0.1
80-100
10
1
PVG100
PV14/BPG20
Helix 4000
80-125
10/1000
1
150-300
100/10000
10
PSM
MSM
PSM-PS15-PS20
(V100)
15/20
0.5
PSM-PS25-PS30
(V100)
25-30
5
PSM-PS40 (V100)
40
5
PSM-LT (V210)
15 & 20
0.5
MSM-T (V100)
1
KVM-T (V200)
1
MSM-RS
10
Supplementary Notes:
FCAL = NUMBER OF LITERS PER PULSE
Kent Meters:
* Some earlier 100-mm meters require the following:
FCAL = 100(PU10/LRP) or 10(PU100/HRP). These meters can be distinguished by the center
pointer dial registration = 1000 liters/rev.
** Applies to 7-digit counters only. The other FCALs apply to the 8-digit counters.
Kent combination meters use a Helix 3000 meter as the main meter and a PSM-T as the secondary
meter. Select the appropriate FCAL from the table above for each of the meters.
The Master 2000 meter has been discontinued.