beautypg.com

Connect gauge tree to valve assembly, Assemble oc bypass valve group – Great Plains V300 Assembly Instructions User Manual

Page 9

background image

Great Plains Mfg., Inc.

Installation Instructions

9

11/08/2006

148-771M

Connect Gauge Tree to Valve Assembly

Refer to Figure 14

65. Screw the center port of tee (60) onto the Rear

port

of adjustment valve (45).

66. Orient gauge tree so that gauge is on Top.Tighten

the connection between tee (60) and check valve
(45) port

.

Assemble OC Bypass Valve Group

Refer to Figure 15

67. Select a (48) 810-432C,

(HYDRAULIC BYPASS VALVE).

Note: Orient the valve (48) so that the adjustment knob

is on Top, toward Right and Front.

68. Select two (51) 811-063C,

(EL 3/4MJIC 3/4MORB).
Screw both into the Front ports of valve (48).
Rotate each to point to the Left and down before
tightening jam nuts.

69. Select a (59) 811-249C,

(TE 9/16MJIC 3/4MORB 9/16MJIC).
Screw the male O-ring boss end into the Rear Bot-
tom port of valve (48). Point the center port of the
tee down before tightening jam nut.

70. Select a (59) 811-249C,

(TE 9/16MJIC 3/4MORB 9/16MJIC).
Screw the male O-ring boss end into the Rear Top
port of valve (48). Point the center port of the tee
Right and down before tightening jam nut.

71. Select a (50) 811-061C,

(TE 9/16MORB 9/16MJIC 9/16MJIC).
Screw the male O-ring boss end into the Rear Top
port of the Bottom tee (59).

72. Select a (55) 811-169C,

(EL 9/16MJIC 9/16FJIC).
Screw female JIC end into the center (Bottom) port
of tee (50)

73. Select the (46) 810-344C,

(VALVE SHUTTLE 9/16FORB PORTS).

Note: The ports of valve (46) are stamped with numbers

“1”, “2” and “3”. Orient the shuttle valve so that port

is to the Front, port

to the Rear and port

at

the Bottom.

74. Select a (53) 811-065C,

(EL 9/16MJIC 9/16MORB).
Screw the male ORB end into the Rear port

of

shuttle valve (46). Orient the JIC end to point down.

75. Select a (56) 811-170C,

(AD 9/16MORB 9/16MJIC).
Screw the male ORB end into the Bottom port

of

shuttle valve (46) and tighten.

76. Select a (62) 811-627C,

(AD 9/16MORB 9/16FJIC).
Screw the male ORB end into Front port

of shut-

tle valve (46) and tighten.

77. Mate the shuttle valve (46) group to the bypass

valve (48) group at fittings (62) and (50). Tighten, so
that valve (46) port

is down, and both valves align

when their Left sides are on a flat surface.

Figure 14

OC Gauge Tree to Valves

25178

60

T

B

R

L

F

R

45

Figure 15

OC Bypass Valve Group

25179

51

T

B

R

L

F

R

48

51

59

59

50

55

46

53

62

56