10

Opener Down Pressure Kit

148-771M

11/08/2006

Assemble OC Valves on Mount

Refer to Figure 16

78. Select the (23) 248-506D,

(OPNR DOWN PRESSURE VALVE MNT).
Orient it so that the smaller of the two vertical
plates is to the Right, and the horizontal base plate
is at the Bottom.

Note: Both valve assemblies mount on the Right side of

the vertical plates. The check valve mounts under
the base.

79. Position the adjustment valve assembly (44) so

that:

• The mounting holes (44) of the adjustment valve

align with the holes

in the small vertical plate.

The notches (45) in the shuttle valve align with

the holes

with the holes in the small vertical

plate.

The notches (47) in the check valve align with

the holes

in the mount base.

Figure 16

Mount Open Center Valves

25180

23

T

B

R

L

F

R

44

45

47

48

46