Chapter 3: Wall Mount Installation 18
WALL MOUNTING PROCEDURE
The wall mounted Beamforming Microphone Array must be placed on a wall facing the
intended conference participants. It can be placed below a video conferencing system such as
COLLABORATE, or in audio-only applications, at eye level with the participants. The face of the
Beamforming Microphone Array should be about 8 to 10 feet from the participants.
» NOTE: Wall mounting MUST be strictly horizontal to assure proper adaptive steering
of audio pickup.
The Wall Mounting Plate is designed with small studs projecting from the plate which fit into slotted
holes on the Mic Mounting Plate to hold the Beamforming Microphone Array to the wall.
1-1/2"
1-1/2"
WALL MOUNT
CUT-OUT
The Wall Mounting Plate is designed to be mounted to either a solid or hollow wall so the fasteners
used to attach the plate to the wall must be appropriate to the wall material to be secure.
Hollow wall mounting gives the advantage of concealed cable routing. Use the following dimensions
for the cable pass-through cut-out for a hollow wall mounting: