13 Beamforming Microphone Array
SOLID-CEILING MOUNTING PROCEDURE
Use the following dimensions for the cable pass-through cut-out for the solid-ceiling mounted
Beamforming Microphone Array:
1-1/2"
3"
1-1/2"
1-1/2"
DROP CEILING CUT-OUT
SOLID CEILING
CUT-OUT
Use the screws to fasten the Ceiling Mounting Plate to the top of the Suspension Column. Place
the plate on the Suspension Column so that the screw heads recess into the hole counter sinks
to allow a flush attachment to the ceiling. (Ignore the short studs on the plate. These are for wall-
mount usage.)
» NOTE: Be certain you have the correct Spanner Post for your installation as determined
by your ceiling height. There are SKU’s for kits containing either a 12-inch or 24-inch
Spanner Post (910-001-005-12 or 910-001-005-24).
Suspension Column
HA
A
B
4X
Ceiling Mounting Plate
Use #1 Phillips screwdriver bit
to avoid damaging screws.