F. tl- sarguide wiring examples cont’d – SARGENT AL - Alarmed Exit User Manual
Page 4

Sample Wiring #2 – TL- (SARGuide) with 12- 58- (Electric Dogging)
combination and 3532 Power Supply with Battery Back-up. 53-,
55- wiring if required.
System Description:
SARGuide is always powered. During a
power outage SARGuide remains powered
and illuminated by 3532 battery back-up
power.
Fire Rated Operation:
If using 12-58- Electric Dogging in
conjunction with SARGuide, a normally
closed fire alarm contact (by others) must
be used and must be wired as shown.
Notes:
1. TL- SARGuide power requirement:
Input Power: 24VDC/VAC
Current draw: 30mA
2. Pigtail assemblies, electric hinge, raceway
and rail connector terminations and wire
colors all match.
3. For 53, 55- and 58- wiring also refer to
individual product instructions provided.
Wire as required by rail type used.
F. TL- SARGuide Wiring Examples cont’d
4
Electric hinge with
8 & 4-pin connectors
Raceway harness with
8 & 4-pin connectors.
Pigtail harness #1
assembly with
8-pin connector
80 series rail prefixes
53- latch bolt monitor swicth
55- signal switch
58- electric dogging
Pigtail harness #2
assembly with
4-pin connector
1
4
2
3
12-TL- 58- 80 Series
Rail with 8 & 4-pin
connectors
EXIT EXIT EX
IT
2, Grey
(TL +24)
1, Violet
(TL
-
24)
120 VAC
L/N/G
L N
Input
120VAC 60HZ
+ - + -
Output
1
Output
2
1 2 3 4 5 6 7 8 9
TB1
TB2
TB3
+
-
Battery
Battery
3532
24VDC, 2Amp
Power Supply
w/Battery Backup
GND
58- (+24) Red, 2
1
7
5
6 4
3
2
8
58- (-24) Black, 1
53- (NC) Orange, 5
53- (C) White, 3
53- (NO) Green, 4
55- (NC) Brown, 8
55- (C) Blue, 6
55- (NO) Yellow, 7
Normally
Closed
Fire Alarm
Connection
By Others
24VDC
Copyright © 2009, SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written
permission of SARGENT Manufacturing is prohibited.
A7711C - 5-1-9